H Series | Horizontal Tanks
Â
200 Series
(1.2m inside diameter):
1,000 – 10,000L capacity
Â
300 Series
(1.8m inside diameter):
4,000 – 40,000L capacity
Â
400 Series
(2.6m inside diameter):
13,650 – 100,000L capacity
Â
500 Series
(3.5m inside diameter):
60,000 – 200,000L capacity
Â
600 Series
(4.0m inside diameter):
100,000 – 300,000L capacity
Primary settlement tanks for sewage treatment plants and commercial waste water treatment works.
24 hour storage capacity for foul pump systems.
Designed with reference to BS EN 13121. All tank shells carry the SPEL 25 Year Warranty and life expectancy in excess of 50 years.
Different tank shell specifications are available dependent upon tank invert levels, ground conditions and ground water levels. (See Installation Guidance section)
Pipe connections available to accommodate most standard sizes.
Pretreatment of wastewater is part of the process of a waste water treatment works (WWTW) from a small private treatment plant through to a large municipal WWTW smaller treatment plants have the primary treatment tank built into the system but larger units have this as a separate tank to increase capacity and for ease of maintenance.
SPEL are ideally placed to supply an comprehensive range of sizes to provide solutions for treatment plant manufacturers, contractors and water companies. Whilst the range starts at 1000L capacity, most systems of this size require larger primary settlement tanks and use the SPEL 400, 500 and 600 models (2.6m, 3.5m, & 4m dia.).
The full range of SPEL accessories are available on all Primary Settlement Tanks, click here or contact our team for more information.
Adoptable foul pump systems normally require two key components, the main Wet Well and offline 24 hour storage. Most water companies require the Wet Well to be constructed from concrete but the offline storage can be GRP, making for a cost effective and robust storage facility.
Again SPEL’s comprehensive range assists designers and contractors with options to deliver the storage required in the most efficient manor. Tanks can be interconnected as part of SPEL’s bespoke manufacturing capacity, which further enhances the design flexibility. Accessories such as Bauer connectors and suction pipes can also be included to provide safe and efficient maintenance.
SPEL Packaged Pumping Stations are available in both Wet Well (V Series) and combined systems where the adopting authority will accept GRP in place of concrete. GRP tanks have a much higher resilience to hydrogen sulphide (H2S).
Here are a range of options that are very often used on Primary Settlement and Buffer Tanks. For a full list of SPEL accessories, click here.
For a full range of sizes, visit our SPEL Tankstor sizing chart here. Below are a selection of sizes that are often used for Primary Settlement and Buffer Tanks, including ‘T’ inlets, baffle walls, suction pipework and benching as required.
Fill out the form below with your details and any info you wish to be considered by our team and we will be in touch shortly.Â
This is the SPEL Puraceptor single chamber model sizing chart. For the difference between single and two chamber models see the explanation below under operation.
Model | Series | Nominal Size (NS) | Catchment Area (m2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out Pipe Diameter** (mm) | Number of Access Shafts(dia. mm) | ||||
Flow (l/s) | L | A | B | C | 450 | 600 | 750 | 900 | 1200 | |||||||
P004 1C/SC | 200 | 4 | 222 | 40 | 400 | 1,720 | 1,225 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – |
P006 1C/SC | 200 | 6 | 333 | 60 | 600 | 2,310 | 1,225 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – |
P010 1C/SC | 200 | 10 | 556 | 100 | 1,000 | 3,410 | 1,225 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – |
P015 1C/SC | 300 | 15 | 833 | 150 | 1,500 | 3,200 | 1,875 | 350 | 1,800 | 1,740 | 225 | 1 | – | 1 | – | – |
P020 1C/SC | 300 | 20 | 1,111 | 200 | 2,000 | 3,540 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | 1 | 1 | – | – |
FP 1C/SC | 300 | 20 | 1,111 | 200 | 2,000 | 4,290 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | 1 | – | – | |
P030 1C/SC | 300 | 30 | 1,667 | 300 | 3,000 | 4,420 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – |
P040 1C/SC | 300 | 40 | 2,222 | 400 | 4,000 | 5,760 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – |
P050 1C/SC | 300 | 50 | 2,778 | 500 | 5,000 | 7,060 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – |
P065 1C/SC | 400 | 65 | 3,611 | 650 | 6,500 | 4,860 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | 1 | – | 2 | – |
P080 1C/SC | 400 | 80 | 4,444 | 800 | 8,000 | 5,700 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | 1 | – | 2 | – |
P100 1C/SC | 400 | 100 | 5,555 | 1,000 | 10,000 | 7,400 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | 1 | – | 2 | – |
P125 1C/SC | 400 | 125 | 6,944 | 1,250 | 12,500 | 8,580 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 2 | – |
P150 1C/SC | 400 | 150 | 8,333 | 1,500 | 15,000 | 10,180 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 2 | – |
P165 1C/SC | 400 | 165 | 9,166 | 1,650 | 16,500 | 11,200 | 2,700 | 500 | 2,550 | 2,450 | 450 | – | 2 | 1 | 1 | – |
P200 1C/SC | 400 | 200 | 11,110 | 2,000 | 20,000 | 13,710 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 1 | 1 | – |
P250 1C/SC | 400 | 250 | 13,888 | 2,500 | 25,000 | 16,750 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 1 | 2 | – |
P280 1C/SC | 400 | 280 | 15,555 | 2,800 | 28,000 | 18,800 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 1 | 2 | 2 | – |
P300 1C/SC | 500 | 300 | 16,665 | 3,000 | 30,000 | 12,410 | 3,650 | 805 | 3,070 | 2,970 | 750 | – | 1 | 2 | 2 | – |
P400 1C/SC | 500 | 400 | 22,220 | 4,000 | 40,000 | 15,760 | 3,650 | 805 | 3,070 | 2,970 | 750 | – | 2 | 2 | 2 | – |
P500 1C/SC | 500 | 500 | 27,775 | 5,000 | 50,000 | 20,530 | 3,650 | 955 | 2,920 | 2,820 | 900 | – | 2 | 2 | 1 | 1 |
P500 1C/SC | 600 | 500 | 27,775 | 5,000 | 50,000 | 16,040 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | 1 | 1 |
P600 1C/SC | 600 | 600 | 33,330 | 6,000 | 60,000 | 19,080 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | – | 2 |
P700 1C/SC | 600 | 700 | 38,888 | 7,000 | 70,000 | 21,460 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 3 | – |
P800 1C/SC | 600 | 800 | 44,440 | 8,000 | 80,000 | 23,020 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 2 | 1 |
All of the above models are available without silt capacity, below are selected models for size comparison. The P1000 model is only available in non silt format. | ||||||||||||||||
P050 1C | 300 | 50 | 2,778 | 500 | – | 5,070 | 1875 | 390 | 1,760 | 1,700 | 300 | – | – | – | 1 | – |
P065 1C | 400 | 65 | 3,611 | 650 | – | 3,710 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | – | 2 | – | |
P100 1C | 400 | 100 | 5,555 | 1,000 | – | 5,250 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 2 | – | |
P125 1C | 400 | 125 | 6,944 | 1,250 | – | 6,090 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | – | 2 | – |
P165 1C | 400 | 165 | 9,166 | 1,650 | – | 7,960 | 2,700 | 500 | 2,550 | 2,450 | 450 | – | 2 | 1 | – | |
P250 1C | 400 | 250 | 13,888 | 2,500 | – | 11,830 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 2 | – | |
P300 1C | 400 | 300 | 16,665 | 3,000 | – | 14,120 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 2 | – | |
P500 1C | 500 | 500 | 27,775 | 5,000 | – | 14,340 | 3,650 | 955 | 2,920 | 2,820 | 900 | – | 2 | 2 | 1 | 1 |
P500 1C | 600 | 500 | 27,775 | 5,000 | – | 11,470 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | 1 | 1 |
P700 1C | 600 | 700 | 38,888 | 7,000 | – | 15,880 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 3 | – |
P1000 1C | 600 | 1,000 | 55,550 | 10,000 | – | 21,407 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 1 | 3 |
*Overall length subject to inlet/outlet and orientation.
**SPEL Separators are designed for a maximum flow (NS/NSB) but can be fitted with larger than the recommended maximum connection size IN/OUT or with the addition of adapters providing the maximum flow (NS/NSB) cannot be exceeded or any increase in the operating level in the SPEL Separator to cause the captured pollutants to escape into the vent connections or through access shaft connections. Any overriding of the above criteria could jeopardise performance to the European Standard BS EN 858-1.
Note: Model FP1C/SC is a special Forecourt separator with 7600 litre spillage holding capacity. Click here for more information on Forecourt Separators.
This is the SPEL Puraceptor two chamber model sizing chart. For the difference between single and two chamber models see the explanation below under operation.
Model | Series | Nominal Size (NS) | Catchment Area (m2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out Pipe Diameter** (mm) | Number of Access Shafts(dia. mm) | ||||
Flow (l/s) | L | A | B | C | 450 | 600 | 750 | 900 | 1200 | |||||||
P006 2C/SC | 200 | 6 | 333 | 60 | 600 | 3,050 | 1,225 | 340 | 1,200 | 1,140 | 160 | – | 1 | 1 | – | – |
P010 2C/SC | 200 | 10 | 556 | 100 | 1,000 | 4,690 | 1,225 | 340 | 1,200 | 1,140 | 160 | – | 1 | 1 | – | – |
P015 2C/SC | 300 | 15 | 833 | 150 | 1,500 | 4,015 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
P020 2C/SC | 300 | 20 | 1,111 | 200 | 2,000 | 4,015 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
FP 2C/SC*** | 300 | 20 | 1,111 | 200 | 2,000 | 5,500 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
P025 2C/SC | 300 | 25 | 1,389 | 250 | 2,500 | 4,290 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
P030 2C/SC | 300 | 30 | 1,667 | 300 | 3,000 | 4,420 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P035 2C/SC | 300 | 35 | 1,944 | 350 | 3,500 | 5,070 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P040 2C/SC | 300 | 40 | 2,222 | 400 | 4,000 | 5,760 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P050 2C/SC | 300 | 50 | 2,778 | 500 | 5,000 | 7,060 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P065 2C/SC | 300 | 65 | 3,611 | 650 | 6,500 | 9,180 | 1,875 | 390 | 1,760 | 1,700 | 300 | 1 | – | 2 | – | – |
P080 2C/SC | 400 | 80 | 4,444 | 800 | 8,000 | 5,700 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | – | 1 | 1 | – |
P100 2C/SC | 400 | 100 | 5,555 | 1,000 | 10,000 | 7,400 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 1 | – |
P125 2C/SC | 400 | 125 | 6,944 | 1,250 | 12,500 | 8,580 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 2 | 1 | – |
P150 2C/SC | 400 | 150 | 8,333 | 1,500 | 15,000 | 10,180 | 2,700 | 500 | 2,550 | 2,450 | 450 | – | – | 2 | 1 | – |
P200 2C/SC | 400 | 200 | 11,110 | 2,000 | 20,000 | 13,710 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 1 | 2 | 1 | – |
P250 2C/SC | 400 | 250 | 13,888 | 2,500 | 25,000 | 16,752 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 1 | 2 | – |
P300 2C/SC | 500 | 300 | 16,665 | 3,000 | 30,000 | 12,530 | 3,650 | 675 | 3,200 | 3,100 | 600 | – | 1 | 2 | – | 1 |
P400 2C/SC | 500 | 400 | 22,220 | 4,000 | 40,000 | 15,980 | 3,650 | 675 | 3,200 | 3,100 | 600 | – | 2 | 2 | 2 | – |
P500 2C/SC | 500 | 500 | 27,775 | 5,000 | 50,000 | 20,530 | 3,650 | 955 | 2,920 | 2,820 | 900 | – | 2 | 2 | 1 | 1 |
P500 2C/SC | 600 | 500 | 27,775 | 5,000 | 50,000 | 16,260 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 1 | 1 | 1 |
P600 2C/SC | 600 | 600 | 33,330 | 6,000 | 60,000 | 19,080 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | 3 | – |
P700 2C/SC | 600 | 700 | 38,888 | 7,000 | 70,000 | 22,270 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 3 | – |
P800 2C/SC | 600 | 800 | 44,440 | 8,000 | 80,000 | 23,020 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 2 | 1 |
P900 2C/SC | 600 | 900 | 50,000 | 9,000 | 90,000 | 24,658 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 1 | 2 |
*Overall length subject to inlet/outlet and orientation.
**SPEL Separators are designed for a maximum flow (NS/NSB) but can be fitted with larger than the recommended maximum connection size IN/OUT or with the addition of adapters providing the maximum flow (NS/NSB) cannot be exceeded or any increase in the operating level in the SPEL Separator to cause the captured pollutants to escape into the vent connections or through access shaft connections. Any overriding of the above criteria could jeopardise performance to the European Standard BS EN 858-1.
Note: Model FP2C/SC is a special Forecourt separator with 7600 litre spillage holding capacity. Click here for more information on Forecourt Separators.
| Model | Series | Meals per Day* | NSG | Tank Length (mm) | Internal Diameter (mm) | Overall Capacity (L) | Grease Capacity (L) | Inlet Invert (m) | Base to Inlet (mm) | Base to Outlet(mm) | Optimum In/Out Pipe Diameter** (mm) | Number of Access Shafts (dia. mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| L | A | B | C | 600 | ||||||||
| GS200/2000 | 200 | 400 | 4 | 2,040 | 1,200 | 2,000 | 160 | 1,020 | 1,000 | 940 | 160 | 2 |
| GS200/3000 | 200 | 600 | 6 | 2,930 | 1,200 | 3,000 | 240 | 1,020 | 1,000 | 940 | 160 | 2 |
| GS200/4000 | 200 | 900 | 9 | 3,810 | 1,200 | 4,000 | 360 | 1,020 | 1,000 | 940 | 160 | 2 |
| GS200/5000 | 200 | 1100 | 11 | 4,700 | 1,200 | 5,000 | 440 | 1,020 | 1,000 | 940 | 160 | 2 |
| GS200/6000 | 200 | 1400 | 14 | 5,578 | 1,200 | 6,000 | 560 | 1,020 | 1,000 | 940 | 160 | 2 |
| GS300/5860 | 300 | 1400 | 14 | 2,690 | 1,800 | 5,860 | 560 | 1,600 | 1,600 | 1,550 | 160 | 2 |
| GS300/9270 | 300 | 1800 | 18 | 4,015 | 1,800 | 9,270 | 720 | 1,600 | 1,600 | 1,550 | 160 | 2 |
| GS300/18200 | 300 | 4000 | 40 | 7,620 | 1,800 | 18,200 | 1600 | 1,600 | 1,600 | 1,550 | 160 | 2 |
| Model | Series | Max. Flow* | Silt Capacity (L) | Overall Length* | Internal Diameter (mm) | Opt In/Out Pipe Diameter (mm) | Number of Access Shafts (dia. mm) | Inlet Invert (mm) |
|---|---|---|---|---|---|---|---|---|
| Flow (l/s) | L | 600 | A | |||||
| WDS 200/1000 | 200 | 1.1 | 250 | 1.17 | 1,200 | 160mm | 1 | – |
| WDS 200/2000 | 200 | 2.2 | 500 | 2.05 | 1,200 | 160mm | 1 | – |
| WDS 200/3000 | 200 | 3.3 | 700 | 2.93 | 1,200 | 160mm | 1 | – |
| WDS 200/4000 | 200 | 4.5 | 1,000 | 3.82 | 1,200 | 160mm | 1 | – |
| WDS 200/5000 | 200 | 5.6 | 1,250 | 4.7 | 1,200 | 160mm | 1 | – |
| WDS 200/6000 | 200 | 6.7 | 1,500 | 5.59 | 1,200 | 160mm | 1 | – |
| WDS 200/7000 | 200 | 7.8 | 1,750 | 6.48 | 1,200 | 160mm | 1 | – |
| WDS 200/8000 | 200 | 9 | 2,000 | 7.36 | 1,200 | 160mm | 1 | – |
| WDS 200/9000 | 200 | 10 | 2,250 | 8.25 | 1,200 | 160mm | 1 | – |
| WDS 200/10,000 | 200 | 11 | 2,500 | 9.13 | 1,200 | 160mm | 1 | – |
| WDS 300/4000 | 300 | 5 | 1,000 | 1.95 | 1,800 | 160mm | 1 | – |
| WDS 300/6000 | 300 | 7 | 1,500 | 2.76 | 1,800 | 160mm | 1 | – |
| WDS 300/8000 | 300 | 9 | 2,000 | 3.54 | 1,800 | 160mm | 1 | – |
| WDS 300/10,000 | 300 | 12 | 2,500 | 4.29 | 1,800 | 160mm | 1 | – |
| Model | Series | Nominal Size (NB) | Catchment Area (M2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out pipe Diameter** (mm) | Number of Access Shafts (dia. mm) | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow (l/s) | A | B | C | 450 | 600 | 750 | ||||||||||
| FR004 SC | 200 | 4 | 222 | 40 | 400 | 1,720 | 1225 | 630 | 1,110 | 1,050 | 160 | 1 | ||||
| FR006 SC | 200 | 6 | 333 | 60 | 600 | 2,270 | 1,225 | 630 | 1,110 | 1,050 | 160 | 1 | ||||
| FR010 SC | 200 | 10 | 556 | 100 | 1,000 | 3,410 | 1,225 | 630 | 1,110 | 1,050 | 160 | 1 | ||||
| FR015 SC | 300 | 15 | 833 | 150 | 1,500 | 2,760 | 1,875 | 350 | 1,800 | 1,740 | 225 | 1 | ||||
| FR020 SC | 300 | 20 | 1,111 | 200 | 2,000 | 3,200 | 1,875 | 350 | 1,800 | 1,740 | 225 | 1 | ||||
| FS2 SC | 300 | 20 | 1,111 | 200 | 2,000 | 4,290 | 1,875 | 350 | 1,800 | 1,740 | 225 | 1 | ||||
| FR030 SC | 300 | 30 | 1,667 | 300 | 3,000 | 4,420 | 1,875 | 390 | 1,760 | 1,700 | 300 | 1 | ||||
| FR040 SC | 300 | 40 | 2,222 | 400 | 4,000 | 5,760 | 1,875 | 390 | 1,760 | 1,700 | 300 | 1 | ||||
| FR050 SC | 300 | 50 | 2,778 | 500 | 5,000 | 7,060 | 1,875 | 390 | 1,760 | 1,700 | 300 | 1 | ||||
| FR065 SC | 400 | 65 | 3,611 | 650 | 6,500 | 4,810 | 2,700 | 425 | 2,625 | 2,525 | 300 | 1 | 1 | |||
| FR080 SC | 400 | 80 | 4,444 | 800 | 8,000 | 5,700 | 2,700 | 425 | 2,625 | 2,525 | 300 | 1 | 1 | |||
| FR100 SC | 400 | 100 | 5,555 | 1,000 | 10,000 | 7,400 | 2,700 | 475 | 2,575 | 2,475 | 450 | 1 | 1 | |||
| FR125 SC | 400 | 125 | 6,944 | 1,250 | 12,500 | 8,580 | 2,700 | 475 | 2,575 | 2,475 | 450 | 1 | 1 | |||
| FR150 SC | 400 | 150 | 8,333 | 1,500 | 15,000 | 10,180 | 2,700 | 475 | 2,575 | 2,475 | 450 | 1 | 1 | |||
| FR165 SC | 400 | 165 | 9,166 | 1,650 | 16,500 | 11,200 | 2,700 | 500 | 2,550 | 2,450 | 450 | 2 | ||||
| FR200 SC | 400 | 200 | 11,110 | 2,000 | 20,000 | 13,710 | 2,700 | 660 | 2,390 | 2,290 | 600 | 2 | ||||
| FR250 SC | 400 | 250 | 13,888 | 2,500 | 25,000 | 16,750 | 2,700 | 660 | 2,390 | 2,290 | 600 | 2 | ||||
| Model | Series | Nominal Size (NB) | Catchment Area (M2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out pipe Diameter** (mm) | Number of Access Shafts (dia. mm) | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow (l/s) | A | B | C | 450 | 600 | 750 | ||||||||||
| FR040 | 300 | 40 | 2,222 | 400 | 4,020 | 1,875 | 390 | 1,760 | 1,700 | 300 | 1 | |||||
| FR050 | 300 | 50 | 2,778 | 500 | 5,070 | 1,875 | 390 | 1,760 | 1,700 | 300 | 1 | |||||
| FR065 | 400 | 65 | 3,611 | 650 | 3,710 | 2,700 | 425 | 2,625 | 2,525 | 300 | 1 | 1 | ||||
| FR080 | 400 | 80 | 4,444 | 800 | 4,400 | 2,700 | 425 | 2,625 | 2,525 | 300 | 1 | 1 | ||||
| FR100 | 400 | 100 | 5,555 | 1000 | 5,250 | 2,700 | 475 | 2,575 | 2,475 | 450 | 1 | 1 | ||||
| FR125 | 400 | 125 | 6,944 | 1250 | 6,090 | 2,700 | 475 | 2,575 | 2,475 | 450 | 1 | 1 | ||||
| FRI50 | 400 | 150 | 8,333 | 1500 | 7,400 | 2,700 | 475 | 2,575 | 2,475 | 450 | 1 | 1 | ||||
| FR165 | 400 | 165 | 9,166 | 1650 | 7,960 | 2,700 | 500 | 2,550 | 2,450 | 450 | 2 | |||||
| FR200 | 400 | 200 | 11,110 | 2000 | 9,600 | 2,700 | 660 | 2,390 | 2,290 | 600 | 2 | |||||
| FR250 | 400 | 250 | 13,888 | 2500 | 11,830 | 2,700 | 660 | 2,390 | 2,290 | 600 | 2 | |||||
| FR300 | 400 | 300 | 16,665 | 3000 | 14,120 | 2,700 | 660 | 2,390 | 2,290 | 600 | 2 | |||||
| FR400 | 500 | 400 | 222,222 | 4,000 | optional | * | 3,650 | – | 3 | – | ||||||
*Overall length subject to inlet/outlet size and orientation
**SPEL Separators are designed for a maximum flow (NS/NSB) but can be fitted with larger than the recommended maximum connection size IN/OUT or with the addition of adapters providing the maximum flow (NS/NSB) cannot be exceeded or any increase in the operating level in the SPEL Separator to cause the captured pollutants to escape into the vent connections or through access shaft connections. Any overriding of the above criteria could jeopardise performance to the European Standard BS EN 858-1.
Note: Model FS2SC is a special forecourt unit with 7600 litre spillage holding capacity.
Model | Series | Nominal Size (NS) | Catchment Area (m2) | Oil Storage (L) | Silt Capacity (L) | Overall Length (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum Inlet dia.** (mm) |
Flow (l/s) | L | |||||||||
P006 2C/SC/M | 300 | 6 | 333 | 60 | 600 | 3,200 | 540 | 1,610 | 1,550 | 160 |
P010 2C/SC/M | 300 | 10 | 556 | 100 | 1,000 | 5,070 | 540 | 1,610 | 1,550 | 160 |
P015 2C/SC/M | 300 | 15 | 833 | 150 | 1,500 | 6,570 | 550 | 1,600 | 1,500 | 225 |
P020 2C/SC/M | 400 | 20 | 1,111 | 200 | 2,000 | 5,250 | 625 | 2,425 | 2,325 | 225 |
P025 2C/SC/M | 400 | 25 | 1,389 | 250 | 2,500 | 6,170 | 625 | 2,425 | 2,325 | 225 |
P030 2C/SC/M | 400 | 30 | 1,667 | 300 | 3,000 | 7,400 | 625 | 2,425 | 2,325 | 300 |
P040 2C/SC/M | 400 | 40 | 2,222 | 400 | 4,000 | 9,930 | For details, please contact our Technical Sales Team | 300 | ||
P060 2C/SC/M | 400 | 60 | 3,333 | 600 | 6,000 | 13,710 | For details, please contact our Technical Sales Team | 300 | ||
P080 2C/SC/M | 500 | 80 | 4,444 | 800 | 8,000 | 10,040 | For details, please contact our Technical Sales Team | 300 | ||
P100 2C/SC/M | 500 | 100 | 5,555 | 1,000 | 10,000 | 12,530 | For details, please contact our Technical Sales Team | 450 | ||
| Model | Series | Nominal Size (NS) | Catchment Area (m2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out Pipe Diameter** (mm) | Number of Access Shafts (dia. mm) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow (l/s) | L | A | B | C | 450 | 750 | 900 | 1200 | ||||||||||
| P006 2C/SC/NG | 200 | 6 | 333 | 60 | 600 | 3,050 | 1225 | 427 | 1,110 | 1,050 | 160 | – | 1 | 1 | – | |||
| P010 2C/SC/NG | 200 | 10 | 556 | 100 | 1,000 | 4,700 | 1,225 | 427 | 1,110 | 1,050 | 160 | – | 3 | – | – | |||
| P015 2C/SC/NG | 300 | 15 | 833 | 150 | 1,500 | 4,020 | 1,875 | 540 | 1,610 | 1,550 | 225 | – | 3 | – | – | |||
| P020 2C/SC/NG | 300 | 20 | 1,111 | 200 | 2,000 | 4,020 | 1,875 | 540 | 1,610 | 1,550 | 225 | – | 3 | – | – | |||
| P025 2C/SC/NG | 300 | 25 | 1,389 | 250 | 2,500 | 4,290 | 1,875 | 540 | 1,610 | 1,550 | 225 | – | 3 | – | – | |||
| P030 2C/SC/NG | 300 | 30 | 1,667 | 300 | 3,000 | 5,070 | 1,875 | 550 | 1,600 | 1,500 | 300 | – | 2 | 1 | – | |||
| P040 2C/SC/NG | 300 | 40 | 2,222 | 400 | 4,000 | 6,570 | 1,875 | 550 | 1,600 | 1,500 | 300 | – | 2 | 1 | – | |||
| P050 2C/SC/NG | 300 | 50 | 2,778 | 500 | 5,000 | 8,260 | 1,875 | 550 | 1,600 | 1,500 | 300 | – | 2 | 1 | – | |||
| P065 2C/SC/NG | 300 | 65 | 3,611 | 650 | 6,500 | 10,220 | 1,875 | 550 | 1,600 | 1,500 | 300 | 1 | 2 | 1 | – | |||
| P065 2C/SC/NG | 400 | 65 | 3,611 | 650 | 6,500 | 5,470 | 2,700 | 665 | 2,385 | 2,285 | 300 | 1 | 1 | 1 | – | |||
| P080 2C/SC/NG | 400 | 80 | 4,444 | 800 | 8,000 | 6,170 | 2,700 | 665 | 2,385 | 2,285 | 300 | 1 | 1 | 1 | – | |||
| P100 2C/SC/NG | 400 | 100 | 5,555 | 1,000 | 10,000 | 7400 | 2,700 | 665 | 2385 | 2285 | 450 | 1 | 1 | 1 | – | |||
| P125 2C/SC/NG | 400 | 125 | 6,944 | 1,250 | 12,500 | 9,600 | 2,700 | 765 | 2,285 | 2,185 | 450 | 1 | 2 | – | 1 | |||
| P150 2C/SC/NG | 400 | 150 | 8,333 | 1,500 | 15,000 | 11,200 | 2,700 | 790 | 2,280 | 2,180 | 450 | 1 | 2 | – | 1 | |||
| P200 2C/SC/NG | 400 | 200 | 11,110 | 2,000 | 20,000 | 16,400 | 2,700 | 940 | 2,130 | 2,030 | 600 | 2 | 2 | – | 1 | |||
| P300 2C/SC/NG | 500 | 300 | 16,665 | 3,000 | 30,000 | 12,530 | 3,650 | 875 | 3,000 | 2,900 | 600 | 2 | 2 | – | 1 | |||
| P400 2C/SC/NG | 500 | 400 | 22,220 | 4,000 | 40,000 | 16,330 | 3,650 | 875 | 3,000 | 2,900 | 600 | 3 | 2 | 2 | – | |||
| Model | Series | Nominal Size (NS) | Catchment Area (m2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out Pipe Diameter* (mm) | Number of Access Shafts (dia. mm) | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow (l/s) | L | A | B | C | 750 | 900 | 1200 | |||||||||
| FP 1C/SCClass 1 Forecourt SeparatorSingle Chamber with Silt Capture | 300 | 20 | 1,111 | 200 | 2,000 | 4,290 | 1,875 | 350 | 1,800 | 1,740 | 225 | 1 | – | – | ||
| FP 2C/SCClass 1 Forecourt SeparatorTwo Chamber with Silt Capture | 300 | 20 | 1,111 | 200 | 2,000 | 5,500 | 1,875 | 350 | 1,800 | 1,740 | 225 | 2 | – | – | ||
| FS2 SCClass 2 Forecourt SeparatorSingle Chamber with Silt Capture | 300 | 20 | 1,111 | 200 | 2,000 | 4,290 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 1 | ||
Model | Series | Nominal Size (NS) | Catchment Area (m2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out Pipe Diameter** (mm) | Number of Access Shafts(dia. mm) | ||||
Flow (l/s) | L | A | B | C | 450 | 600 | 750 | 900 | 1200 | |||||||
P006 2C/SC | 200 | 6 | 333 | 60 | 600 | 3,050 | 1,225 | 340 | 1,200 | 1,140 | 160 | – | 1 | 1 | – | – |
P010 2C/SC | 200 | 10 | 556 | 100 | 1,000 | 4,690 | 1,225 | 340 | 1,200 | 1,140 | 160 | – | 1 | 1 | – | – |
P015 2C/SC | 300 | 15 | 833 | 150 | 1,500 | 4,015 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
P020 2C/SC | 300 | 20 | 1,111 | 200 | 2,000 | 4,015 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
FP 2C/SC*** | 300 | 20 | 1,111 | 200 | 2,000 | 5,500 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
P025 2C/SC | 300 | 25 | 1,389 | 250 | 2,500 | 4,290 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | – | 2 | – | – |
P030 2C/SC | 300 | 30 | 1,667 | 300 | 3,000 | 4,420 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P035 2C/SC | 300 | 35 | 1,944 | 350 | 3,500 | 5,070 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P040 2C/SC | 300 | 40 | 2,222 | 400 | 4,000 | 5,760 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P050 2C/SC | 300 | 50 | 2,778 | 500 | 5,000 | 7,060 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | 2 | – | – |
P065 2C/SC | 300 | 65 | 3,611 | 650 | 6,500 | 9,180 | 1,875 | 390 | 1,760 | 1,700 | 300 | 1 | – | 2 | – | – |
P080 2C/SC | 400 | 80 | 4,444 | 800 | 8,000 | 5,700 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | – | 1 | 1 | – |
P100 2C/SC | 400 | 100 | 5,555 | 1,000 | 10,000 | 7,400 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 1 | – |
P125 2C/SC | 400 | 125 | 6,944 | 1,250 | 12,500 | 8,580 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 2 | 1 | – |
P150 2C/SC | 400 | 150 | 8,333 | 1,500 | 15,000 | 10,180 | 2,700 | 500 | 2,550 | 2,450 | 450 | – | – | 2 | 1 | – |
P200 2C/SC | 400 | 200 | 11,110 | 2,000 | 20,000 | 13,710 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 1 | 2 | 1 | – |
P250 2C/SC | 400 | 250 | 13,888 | 2,500 | 25,000 | 16,752 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 1 | 2 | – |
P300 2C/SC | 500 | 300 | 16,665 | 3,000 | 30,000 | 12,530 | 3,650 | 675 | 3,200 | 3,100 | 600 | – | 1 | 2 | – | 1 |
P400 2C/SC | 500 | 400 | 22,220 | 4,000 | 40,000 | 15,980 | 3,650 | 675 | 3,200 | 3,100 | 600 | – | 2 | 2 | 2 | – |
P500 2C/SC | 500 | 500 | 27,775 | 5,000 | 50,000 | 20,530 | 3,650 | 955 | 2,920 | 2,820 | 900 | – | 2 | 2 | 1 | 1 |
P500 2C/SC | 600 | 500 | 27,775 | 5,000 | 50,000 | 16,260 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 1 | 1 | 1 |
P600 2C/SC | 600 | 600 | 33,330 | 6,000 | 60,000 | 19,080 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | 3 | – |
P700 2C/SC | 600 | 700 | 38,888 | 7,000 | 70,000 | 22,270 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 3 | – |
P800 2C/SC | 600 | 800 | 44,440 | 8,000 | 80,000 | 23,020 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 2 | 1 |
P900 2C/SC | 600 | 900 | 50,000 | 9,000 | 90,000 | 24,658 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 1 | 2 |
Model | Series | Nominal Size (NS) | Catchment Area (m2) | Oil Storage (L) | Silt Capacity (L) | Overall Length* (mm) | Overall Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum In/Out Pipe Diameter** (mm) | Number of Access Shafts(dia. mm) | ||||
Flow (l/s) | L | A | B | C | 450 | 600 | 750 | 900 | 1200 | |||||||
P004 1C/SC | 200 | 4 | 222 | 40 | 400 | 1,720 | 1,225 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – |
P006 1C/SC | 200 | 6 | 333 | 60 | 600 | 2,310 | 1,225 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – |
P010 1C/SC | 200 | 10 | 556 | 100 | 1,000 | 3,410 | 1,225 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – |
P015 1C/SC | 300 | 15 | 833 | 150 | 1,500 | 3,200 | 1,875 | 350 | 1,800 | 1,740 | 225 | 1 | – | 1 | – | – |
P020 1C/SC | 300 | 20 | 1,111 | 200 | 2,000 | 3,540 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | 1 | 1 | – | – |
FP 1C/SC | 300 | 20 | 1,111 | 200 | 2,000 | 4,290 | 1,875 | 350 | 1,800 | 1,740 | 225 | – | 1 | – | – | |
P030 1C/SC | 300 | 30 | 1,667 | 300 | 3,000 | 4,420 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – |
P040 1C/SC | 300 | 40 | 2,222 | 400 | 4,000 | 5,760 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – |
P050 1C/SC | 300 | 50 | 2,778 | 500 | 5,000 | 7,060 | 1,875 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – |
P065 1C/SC | 400 | 65 | 3,611 | 650 | 6,500 | 4,860 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | 1 | – | 2 | – |
P080 1C/SC | 400 | 80 | 4,444 | 800 | 8,000 | 5,700 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | 1 | – | 2 | – |
P100 1C/SC | 400 | 100 | 5,555 | 1,000 | 10,000 | 7,400 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | 1 | – | 2 | – |
P125 1C/SC | 400 | 125 | 6,944 | 1,250 | 12,500 | 8,580 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 2 | – |
P150 1C/SC | 400 | 150 | 8,333 | 1,500 | 15,000 | 10,180 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 2 | – |
P165 1C/SC | 400 | 165 | 9,166 | 1,650 | 16,500 | 11,200 | 2,700 | 500 | 2,550 | 2,450 | 450 | – | 2 | 1 | 1 | – |
P200 1C/SC | 400 | 200 | 11,110 | 2,000 | 20,000 | 13,710 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 1 | 1 | – |
P250 1C/SC | 400 | 250 | 13,888 | 2,500 | 25,000 | 16,750 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 1 | 2 | – |
P280 1C/SC | 400 | 280 | 15,555 | 2,800 | 28,000 | 18,800 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 1 | 2 | 2 | – |
P300 1C/SC | 500 | 300 | 16,665 | 3,000 | 30,000 | 12,410 | 3,650 | 805 | 3,070 | 2,970 | 750 | – | 1 | 2 | 2 | – |
P400 1C/SC | 500 | 400 | 22,220 | 4,000 | 40,000 | 15,760 | 3,650 | 805 | 3,070 | 2,970 | 750 | – | 2 | 2 | 2 | – |
P500 1C/SC | 500 | 500 | 27,775 | 5,000 | 50,000 | 20,530 | 3,650 | 955 | 2,920 | 2,820 | 900 | – | 2 | 2 | 1 | 1 |
P500 1C/SC | 600 | 500 | 27,775 | 5,000 | 50,000 | 16,040 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | 1 | 1 |
P600 1C/SC | 600 | 600 | 33,330 | 6,000 | 60,000 | 19,080 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | – | 2 |
P700 1C/SC | 600 | 700 | 38,888 | 7,000 | 70,000 | 21,460 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 3 | – |
P800 1C/SC | 600 | 800 | 44,440 | 8,000 | 80,000 | 23,020 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 2 | 1 |
All of the above models are available without silt capacity, below are selected models for size comparison. The P1000 model is only available in non silt format. | ||||||||||||||||
P050 1C | 300 | 50 | 2,778 | 500 | – | 5,070 | 1875 | 390 | 1,760 | 1,700 | 300 | – | – | – | 1 | – |
P065 1C | 400 | 65 | 3,611 | 650 | – | 3,710 | 2,700 | 425 | 2,625 | 2,525 | 300 | – | – | 2 | – | |
P100 1C | 400 | 100 | 5,555 | 1,000 | – | 5,250 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | 2 | – | |
P125 1C | 400 | 125 | 6,944 | 1,250 | – | 6,090 | 2,700 | 475 | 2,575 | 2,475 | 450 | – | – | – | 2 | – |
P165 1C | 400 | 165 | 9,166 | 1,650 | – | 7,960 | 2,700 | 500 | 2,550 | 2,450 | 450 | – | 2 | 1 | – | |
P250 1C | 400 | 250 | 13,888 | 2,500 | – | 11,830 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 2 | – | |
P300 1C | 400 | 300 | 16,665 | 3,000 | – | 14,120 | 2,700 | 660 | 2,390 | 2,290 | 600 | – | 2 | 2 | – | |
P500 1C | 500 | 500 | 27,775 | 5,000 | – | 14,340 | 3,650 | 955 | 2,920 | 2,820 | 900 | – | 2 | 2 | 1 | 1 |
P500 1C | 600 | 500 | 27,775 | 5,000 | – | 11,470 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | 1 | 1 |
P700 1C | 600 | 700 | 38,888 | 7,000 | – | 15,880 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 3 | – |
P1000 1C | 600 | 1,000 | 55,550 | 10,000 | – | 21,407 | 4,150 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 1 | 3 |
| Model | Nominal Size (NSB) | Peak Flow (l/s) | Catchment Area (m2) | Oil Storage (L) | Silt Storage (L) | Length (mm) | Internal Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum in/out Pipe Diameter (mm) for Orientation* | Number of Access Shafts A-C Diameter (mm) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow (l/s) | NSB x 15 | NSB x 100 | L | W | A | B | C | 750* | 900 | |||||||||
| 103 C1/SC | 3 | 30 | 1,667 | 45 | 300 | 1,550 | 1,300 | 500 | 1,015 | 965 | 160 | – | – | |||||
| 204 C1/SC | 4 | 40 | 2,222 | 60 | 400 | 1,860 | 1,200 | 550 | 1,350 | 1,300 | 300 | 1 | – | |||||
| 206 C1/SC | 6 | 60 | 3,333 | 90 | 600 | 2,120 | 1,200 | 550 | 1,350 | 1,300 | 300 | 1 | – | |||||
| 208 C1/SC | 8 | 80 | 4,444 | 120 | 800 | 2,270 | 1,200 | 550 | 1,350 | 1,300 | 300 | 1 | – | |||||
| 210 C1/SC | 10 | 100 | 5,556 | 150 | 1,000 | 2,920 | 1,200 | 550 | 1,350 | 1,300 | 300 | 1 | – | |||||
| 212 C1/SC | 12 | 120 | 6,667 | 180 | 1,200 | 3,570 | 1,200 | 560 | 1,350 | 1,300 | 300 | 1 | – | |||||
| 215 C1/SC | 15 | 150 | 8,333 | 225 | 1,500 | 4,237 | 1,200 | 560 | 1,350 | 1,300 | 300 | 1 | – | |||||
| 320 C1/SC | 20 | 200 | 11,111 | 300 | 2,000 | 3,200 | 1,800 | 700 | 1,450 | 1,350 | 450 | – | – | |||||
| 325 C1/SC | 25 | 250 | 13,889 | 375 | 2,500 | 3,540 | 1,800 | 700 | 1,450 | 1,350 | 450 | – | – | |||||
| 330 C1/SC | 30 | 300 | 16,667 | 450 | 3,000 | 4,420 | 1,800 | 700 | 1,450 | 1,350 | 450 | 1 | 1 | |||||
| 340 C1/SC | 40 | 400 | 22,222 | 600 | 4,000 | 5,760 | 1,800 | 740 | 1,410 | 1,310 | 450 | 1 | – | |||||
| 345 C1/SC | 45 | 450 | 25,000 | 675 | 4,500 | 6,570 | 1,800 | 740 | 1,410 | 1,310 | 450 | 1 | – | |||||
| 350 C1/SC | 50 | 500 | 27,778 | 750 | 5,000 | 7,060 | 1,800 | 740 | 1,410 | 1,310 | 450 | 1 | – | |||||
| 460 C1/SC | 60 | 600 | 33,333 | 900 | 6,000 | 4,400 | 2,600 | 950 | 2,100 | 2,000 | 600 | 1 | 1 | |||||
| 470 C1/SC | 70 | 700 | 38,889 | 1,050 | 7,000 | 5,250 | 2,600 | 950 | 2,100 | 2,000 | 600 | 1 | 1 | |||||
| 480 C1/SC | 80 | 800 | 44,444 | 1,200 | 8,000 | 6,170 | 2,600 | 950 | 2,100 | 2,000 | 600 | 1 | 1 | |||||
| 4100 C1/SC | 100 | 1,000 | 55,556 | 1,500 | 10,000 | 7,400 | 2,600 | 1,100 | 1,950 | 1,850 | 750 | 1 | 1 | |||||
| 4125 C1/SC | 125 | 1,250 | 69,444 | 1,875 | 12,500 | 9,050 | 2,600 | 1,100 | 1,950 | 1,850 | 750 | 1 | 1 | |||||
| 4150 C1/SC | 150 | 1,500 | 83,333 | 2,250 | 15,000 | 9,950 | 2,600 | 1,100 | 1,950 | 1,850 | 750 | – | 2 | |||||
| 4160 C1/SC | 160 | 1,600 | 88,889 | 2,400 | 16,000 | 11,830 | 2,600 | 1,250 | 1,800 | 1,700 | 750 | 1 | 2 | |||||
| 5180 C1/SC | 180 | 1,800 | 100,000 | 2,700 | 18,000 | 7,470 | 3,500 | 1,185 | 2,690 | 2,550 | 900 | 1 | 2 | |||||
| 5200 C1/SC | 200 | 2,000 | 111,000 | 3,000 | 20,000 | 8,530 | 3,500 | 1,185 | 2,425 | 2,325 | 1,200 | 1 | 2 | |||||
| 5250 C1/SC | 250 | 2,500 | 139,000 | 3,750 | 25,000 | 10,040 | 3,500 | 1,185 | 2,425 | 2,325 | 1,200 | 1 | 2 | |||||
| 6300 C1/SC | 300 | 3,000 | 167,000 | 4,500 | 30,000 | 10,310 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 2 | |||||
| 6350 C1/SC | 350 | 3,500 | 194,000 | 5,250 | 35,000 | 11,500 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 2 | 3 | |||||
| 6400 C1/SC | 400 | 4,000 | 222,000 | 6,000 | 40,000 | 12,690 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 2 | 3 | |||||
| 6500 C1/SC | 500 | 5,000 | 278,000 | 7,500 | 50,000 | 15,870 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 2 | 4 | |||||
| 6600 C1/SC | 600 | 6,000 | 333,000 | 9,000 | 60,000 | 18,260 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 4 | |||||
| 6700 C1/SC | 700 | 7,000 | 389,000 | 10,500 | 70,000 | 22,250 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 2 | 5 | |||||
| 6500 C1 | 500 | 5,000 | 27.8 | 7,500 | Nil | 11,910 | 4,150 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 4 | |||||
| 6600 C1 | 600 | 6,000 | 33.3 | 9,000 | Nil | 13,510 | 4,150 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 4 | |||||
| 6700 C1 | 700 | 7,000 | 38.9 | 10,500 | Nil | 16,650 | 4,150 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 5 | |||||
| 6800 C1 | 800 | 8,000 | 44.4 | 12,000 | Nil | 19,890 | 4,150 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 6 | |||||
| Model | Series | Treated Flow Rate (l/s) | Maximum Design Storm Flow (l/s) | Catchment area* (m²) | Head Loss Storm Flow (mm) | Overall Diameter (mm) | Overall Chamber Height (mm) | Inlet to Base (mm) | Inlet Invert (mm) | Silt Capacity (L) | Hydrocarbon Capacity (L) | Pipe Size dia. (mm) | Access Opening (mm) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SHV 200/30 | 200 | 30 | 122 | 4,000 | 180 | 1,225 | 2,680 | 1,600 | 1,080 | 360 | 220 | 300 | Ø750 |
| SHV 300/70 | 300 | 70 | 280 | 9,333 | 255 | 1,825 | 3,800 | 2,400 | 1,400 | 1,200 | 900 | 450 | Ø900 |
| SHV 400/200 | 400 | 200 | 650 | 26,665 | 350 | 2,700 | 5,000 | 3,300 | 1,700 | 3,450 | 2,000 | 600 | Ø1,200 |
| SHV 500/400 | 500 | 400 | 900 | 53,333 | 500 | 3,540 | 5,390 | 3,000 | 2,390 | 5,000 | 4,800 | 750 | Ø1,200 |
| Model | Series | Max. Flow (l/s) | Catchment Area Based on 65mm/hr | Oil Storage (L) | Silt Capacity (L) | Tank Length (mm) | Internal Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum in/out Pipe Diameter* (mm) | Number of Access Shafts (dia. mm) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A | B | C | 450 | 600 | 750 | 900 | 1,200 | |||||||||||||
| P004/1C/ESR | 200 | 4 | 222 | 40 | 400 | 1,710 | 1,220 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – | ||||
| P006/1C/ESR | 200 | 6 | 333 | 60 | 600 | 2,310 | 1,220 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – | ||||
| P010/1C/ESR | 200 | 10 | 556 | 100 | 1,000 | 3,400 | 1,220 | 630 | 1,110 | 1,050 | 160 | – | – | 1 | – | – | ||||
| P015/1C/ESR | 300 | 15 | 833 | 150 | 1,500 | 3,200 | 1,800 | 350 | 1,800 | 1,740 | 225 | 1 | – | 1 | – | – | ||||
| P020/1C/ESR | 300 | 20 | 1,111 | 200 | 2,000 | 3,540 | 1,800 | 350 | 1,800 | 1,740 | 225 | – | 1 | 1 | – | – | ||||
| P030/1C/ESR | 300 | 30 | 1,667 | 300 | 3,000 | 4,420 | 1,80 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – | ||||
| P040/1C/ESR | 300 | 40 | 2,222 | 400 | 4,000 | 5,760 | 1,800 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – | ||||
| P050/1C/ESR | 300 | 50 | 2,778 | 500 | 5,000 | 7,060 | 1,800 | 390 | 1,760 | 1,700 | 300 | – | 1 | – | 1 | – | ||||
| P065/1C/ESR | 400 | 65 | 3,611 | 650 | 6,500 | 4,810 | 2,600 | 425 | 2,625 | 2,525 | 300 | – | 1 | – | 2 | – | ||||
| P080/1C/ESR | 400 | 80 | 4,444 | 800 | 8,000 | 5,700 | 2,600 | 425 | 2,625 | 2,525 | 300 | – | 1 | – | 2 | – | ||||
| P100/1C/ESR | 400 | 100 | 5,555 | 1,000 | 10,000 | 7,400 | 2,600 | 475 | 2,575 | 2,475 | 450 | – | 1 | – | 2 | – | ||||
| P125/1C/ESR | 400 | 125 | 6,944 | 1,250 | 12,500 | 8,580 | 2,600 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 2 | – | ||||
| P150/1C/ESR | 400 | 150 | 8,333 | 1,500 | 15,000 | 10,180 | 2,600 | 475 | 2,575 | 2,475 | 450 | – | – | 1 | 2 | – | ||||
| P165/1C/ESR | 400 | 165 | 9,166 | 1,650 | 16,500 | 11,200 | 2,600 | 500 | 2,550 | 2,450 | 450 | – | – | 1 | 2 | – | ||||
| P200/1C/ESR | 400 | 200 | 11,110 | 2,000 | 20,000 | 13,710 | 2,600 | 660 | 2,390 | 2,290 | 600 | – | 1 | 2 | 1 | – | ||||
| P250/1C/ESR | 400 | 250 | 13,888 | 2,500 | 25,000 | 16,750 | 2,600 | 660 | 2,390 | 2,290 | 600 | – | 1 | 2 | 2 | – | ||||
| P280/1C/ESR | 400 | 280 | 15,555 | 2,800 | 28,000 | 18,800 | 2,600 | 660 | 2,390 | 2,290 | 600 | – | 1 | 2 | 2 | – | ||||
| P300/1C/ESR | 500 | 300 | 16,665 | 3,000 | 30,000 | 12,410 | 3,500 | 805 | 3,070 | 2,970 | 750 | – | 1 | 2 | 2 | – | ||||
| P400/1C/ESR | 500 | 400 | 22,220 | 4,000 | 40,000 | 15,760 | 3,500 | 805 | 3,070 | 2,970 | 750 | – | 2 | 2 | 2 | – | ||||
| P500/1C/ESR | 500 | 500 | 27,775 | 5,000 | 50,000 | 20,530 | 3,500 | 955 | 2,920 | 2,820 | 900 | – | 2 | 2 | 1 | 1 | ||||
| P500/1C/ESR | 600 | 500 | 27,775 | 5,000 | 50,000 | 16,040 | 4,000 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | 1 | 1 | ||||
| P600/1C/ESR | 600 | 600 | 33,330 | 6,000 | 60,000 | 19,080 | 4,000 | 925 | 3,250 | 3,150 | 900 | – | 2 | 2 | – | 2 | ||||
| P700/1C/ESR | 600 | 700 | 38,888 | 7,000 | 70,000 | 21,470 | 4,000 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 3 | – | ||||
| P800/1C/ESR | 600 | 800 | 44,440 | 8,000 | 80,000 | 23,020 | 4,000 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | 2 | 1 | ||||
| P900/1C/ESR | 600 | 900 | 49,846 | 9,000 | 90,000 | 24,658 | 4,000 | 925 | 3,250 | 3,150 | 900 | – | 3 | 2 | – | 3 | ||||
| Model | Series | Treated Flow Rate | Maximum Flow | Connectible / Catchment area (m²)* | Oil Storage (litres) | Silt Capacity (litres) | Tank Length (mm) | Internal Diameter (mm) | Inlet Invert (mm) | Base to Inlet (mm) | Base to Outlet (mm) | Optimum in / out pipe diameter ** (mm) | Number of Access Shafts A-C*** (dia. mm) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| L | A | B | C | 750 | 900 | 1200 | |||||||||||||
| 210C1/ESR | 200 | 10 | 100 | 1,333 | 150 | 1,000 | 2,920 | 1,220 | 550 | 1,350 | 1,300 | 300 | 1 | – | – | ||||
| 212C1/ESR | 200 | 12 | 120 | 1,600 | 180 | 1200 | 3,570 | 1,220 | 550 | 1,350 | 1,300 | 300 | 1 | – | – | ||||
| 215C1/ESR | 200 | 15 | 150 | 2,000 | 225 | 1,500 | 4,237 | 1,220 | 550 | 1,350 | 1,300 | 300 | 1 | – | – | ||||
| 320C1/ESR | 300 | 20 | 200 | 2,665 | 300 | 2,000 | 3,200 | 1,800 | 700 | 1,450 | 1,350 | 450 | – | – | – | ||||
| 325C1/ESR | 300 | 25 | 250 | 3,333 | 375 | 2,500 | 3,535 | 1,800 | 700 | 1,450 | 1,350 | 450 | – | – | – | ||||
| 330C1/ESR | 300 | 30 | 300 | 4,000 | 450 | 3,000 | 4,420 | 1,800 | 700 | 1,450 | 1,350 | 450 | 1 | 1 | – | ||||
| 340C1/ESR | 300 | 40 | 400 | 5,333 | 600 | 4,000 | 5,760 | 1,800 | 740 | 1,410 | 1,310 | 450 | 1 | – | – | ||||
| 345C1/ESR | 300 | 45 | 450 | 6,000 | 675 | 4,500 | 6,563 | 1,800 | 740 | 1,410 | 1,310 | 450 | 1 | – | – | ||||
| 350/C1/ESR | 300 | 50 | 500 | 6,665 | 750 | 5,000 | 7,060 | 1,800 | 740 | 1,410 | 1,310 | 450 | 1 | – | – | ||||
| 460C1/ESR | 400 | 60 | 600 | 8,000 | 900 | 6,000 | 4,400 | 2,600 | 950 | 2,100 | 2,000 | 600 | 1 | 1 | – | ||||
| 470C1/ESR | 400 | 70 | 700 | 9,333 | 1,050 | 7,000 | 5,250 | 2,600 | 950 | 2,100 | 2,000 | 600 | 1 | 1 | – | ||||
| 480C1/ESR | 400 | 80 | 800 | 10,665 | 1,200 | 8,000 | 6,170 | 2,600 | 950 | 2,100 | 2,000 | 600 | 1 | 1 | – | ||||
| 4100C1/ESR | 400 | 100 | 1,000 | 13,333 | 1,500 | 10,000 | 7,400 | 2,600 | 1,100 | 1,950 | 1,850 | 750 | 1 | 1 | – | ||||
| 4125C1/ESR | 400 | 125 | 1,250 | 16,665 | 1,875 | 12,500 | 9,000 | 2,600 | 1,100 | 1,950 | 1,850 | 750 | 1 | 1 | – | ||||
| 4150C1/ESR | 400 | 150 | 1,500 | 20,000 | 2,250 | 15,000 | 9,930 | 2,600 | 1,100 | 1,950 | 1,850 | 750 | – | 2 | – | ||||
| 4160C1/ESR | 400 | 160 | 1,600 | 21,333 | 2,400 | 16,000 | 11,830 | 2,600 | 1,250 | 1,950 | 1,850 | 750 | 1 | 2 | – | ||||
| 5180C1/ESR | 500 | 180 | 1,800 | 24,000 | 2,700 | 18,000 | 7,472 | 3,500 | 1,185 | 2,690 | 2,550 | 900 | 1 | 2 | – | ||||
| 5200C1/ESR | 500 | 200 | 2,000 | 26,665 | 3,000 | 20,000 | 8,530 | 3,500 | 1,185 | 2,570 | 2,355 | 1,200 | 1 | 2 | – | ||||
| 5250C1/ESR | 500 | 250 | 2,500 | 33,333 | 3,750 | 25,000 | 10,040 | 3,500 | 1,185 | 2,690 | 2,355 | 1,200 | |||||||
| 6300C1/ESR | 600 | 300 | 3,000 | 40,000 | 4,500 | 30,000 | 10,310 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 2 | – | ||||
| 6350C1/ESR | 600 | 350 | 3,500 | 46,665 | 5,250 | 35,000 | 11,500 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 2 | 3 | – | ||||
| 6400C1/ESR | 600 | 400 | 4,000 | 53,333 | 6,000 | 40,000 | 12,690 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 2 | 3 | – | ||||
| 6500C1/ESR | 600 | 500 | 5,000 | 66,665 | 7,500 | 50,000 | 15,880 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 2 | 4 | – | ||||
| 6600C1/ESR | 600 | 600 | 6,000 | 80,000 | 9,000 | 60,000 | 18,256 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | 1 | 5 | |||||
| 6700C1/ESR | 600 | 700 | 7,000 | 93,333 | 10,500 | 70,000 | 22,250 | 4,000 | 1,325 | 2,850 | 2,675 | 1,200 | |||||||