Search

SPEL Grease Separators

SPEL Grease Separators are designed for use wherever it is necessary to capture fats, oils and greases (FOGs) from process water, such as trade effluent or restaurant wash water. SPEL Grease separators are available from 1,300 litre to 18,200 litre depending on the specific site requirements.    

Class 2 Full Retention Separators

For more technical information on our SPEL separators please click here to go to our SPEL Separator Solutions page

Product Range

100 Series

1,300L

NSG 2

200 Meals/day

 

200 Series

2,000L – 6,000L

NSG 4-14

400 – 1,400 Meals/day

 

300 Series

5,860L – 18,200L

NSG 14-40

1,400 – 4,000 Meals/day

 

Larger/intermediate sizes available, contact our team for more information.

Applications

  • Commercial/large catering kitchens Fast food preparation plants
  • Food processing plants
  • Butchers
  • Abattoirs
  • Vegetable oil refineries

 

Alarm

Dedicated grease trap alarm available.

Shell Design

Designed with reference to BS EN 13121. All tank shells carry the SPEL 25 Year Warranty and life expectancy in excess of 50 years.

Shell Specifications

Different tank shell specifications are available dependent upon tank invert levels, ground conditions and ground water levels. (See Installation Guidance section)

Inlet/Outlet Connections

Standard pipe size – 160mm diameter PVCU socket/spigot (larger sizes available on request).

The nine inlet/outlet options below are available to assist with design and installation.

ModelSeriesMeals per Day*NSGTank Length (mm)Internal Diameter (mm)Overall Capacity (L)Grease Capacity (L)Inlet Invert (m)Base to Inlet (mm)Base to Outlet(mm)Optimum In/Out Pipe Diameter** (mm)Number of Access Shafts (dia. mm)
    L   ABC 600
GS100/130010020021,5501,2501,300801,0151,0159651602
GS200/200020040042,0401,2002,0001601,0201,0009401602
GS200/300020060062,9301,2003,0002401,0201,0009401602
GS200/400020090093,8101,2004,0003601,0201,0009401602
GS200/50002001100114,7001,2005,0004401,0201,0009401602
GS200/60002001400145,5781,2006,0005601,0201,0009401602
GS300/58603001400142,6901,8005,8605601,6001,6001,5501602
GS300/92703001800184,0151,8009,2707201,6001,6001,5501602
GS300/182003004000407,6201,80018,20016001,6001,6001,5501602

*Based on restaurant meals (BS 825-2)

**SPEL Separators are designed for a maximum flow (NS/NSB) but can be fitted with larger than the recommended maximum connection size IN/OUT or with the addition of adapters providing the maximum flow (NS/NSB) cannot be exceeded or any increase in the operating level in the SPEL Separator to cause the captured pollutants to escape into the vent connections or through access shaft connections. Any overriding of the above criteria could jeopardise performance to the European Standard BS EN 858-1.

Larger/intermediate sizes available, contact our team for more information.

Companies who pollute the environment can be hit with unlimited financial penalties from the Environment Agency from today (11 December 2023).’ gov.uk

Shaft Extensions

All SPEL Separator Systems have a large range of technical accessories to ease maintenance and monitoring.

Circular access shafts are supplied in 450, 600, 700, 900 and 1200mm diameter. Rectangular shafts are supplied in 800, 900 and 1000mm X 1000/1250/1500mm. GRP ladders can be incorporated for more access, complete with stainless steel fixings.

Rectangular Shafts
Stub Access Shafts
Flanged joint stub access shaft with extension shaft
600,750 and 900mm diameter.
Socket joint stub access shaft with extension shaft
600, 750, 900 and 1200mm diameter

200/300 Series

Shafts can be laminated onto the tank up to a maximum height of 1.2m. Above this height extension shafts can be supplied separately for on-site fitting during installation.

400 Series

Shafts up to 400mm high are laminated onto the tank. Above this height extension shafts can be supplied separately for on-site fitting during installation.

500 Series

Shafts up to 300mm high are laminated onto the tank. Above this height extension shafts can be supplied separately for on-site fitting during installation.

600 Series

Stub access shafts are fitted 100mm high and extension access shafts fitted as 500 series. Above this height extension shafts can be supplied separately for on-site fitting during installation.

Extension Shafts

These are supplied in 500mm increments and are available in different laminate specs to suit site-specific invert levels and applications.

Guide Rails for Coalescers

Note: only applicable to units fitted with the SPEL Coalescer

Normal servicing of the smaller SPEL Separators frequently requires emptying the unit completely. Guide rails provide access for the coalescer units to be taken out, cleaned and returned and guided accurately to their seating positions. However larger SPEL Separators may only require the hydrocarbon pollutants and silt to be removed.

In order to limit the servicing to sucking off the fuel/oil from the top and the silt from the bottom guide rails are required to ensure coalescer units are replaced into their correct positions.

The system is robust, manufactured throughout in stainless steel and the action positive, leaving no doubt the coalescer unit is located properly.

Brackets fixed to the top and bottom of the coalescer unit simply engage the stainless steel guide rail fixed to the top of the stub access shaft. The coalescer is then lowered in the normal way, being guided at the correct angle into the conical base unit which locates the coalescer unit into its final position.

Extension guide rails can be incorporated into SPEL extension shafts to suit (preferably when ordered with the separator).

SPEL coalescer unit lifting/locating/locking system for positive location and security locking

SPEL coalescer units lowered into the separator with the SPEL guide rail system are easily guided into the base unit’s conical moulding to automatically sit correctly.

However, when the separator is full of water, debris or silt accumulated over a period, this could prevent the coalescer unit from re-seating correctly after servicing.

The coalescer unit lifting/locating/locking system provides assurance the coalescer unit is seated correctly and can be locked into position to prevent tampering.

The system is particularly suitable in SPEL Separator + Econoskim® systems where the total contents of the separator are not emptied on servicing.

The system comprises a robust stainless steel lifting and lowering handle that locates on the guide rail system. When the coalescer unit is correctly located in the conical seating in the separator, the handle will align with guide rail top bracket i.e.. the handles slotted holes with the top bracket clip locking groove, see diagram.

When aligned the stainless steel clip can be located through the slots and lock into position on the top bracket.

The stainless steel lifting handle can be extended to suit deep tank inverts and provide easy access for lifting manually or with the SPEL tripod and hoist.

Automatic Alarms/Monitoring Systems

Alarm systems are available for all SPEL separators. These include probes for oil, silt and high level. There are also a range of control panels including solar power, more detail on our alarm systems can be found here.

Control Panels

Alarm Probes

idOil-OIL oil probe

Detects oil and indicates when the separator’s oil storage is full.

This probe is required in order for a treatment device to comply with BS EN 858.

idOil-SLU silt probe

Monitors the silt layer in the oil separator and indicates when the silt layer has reached its maximum level.

idOil-LIQ high liquid level probe

Indicates when the liquid level in the oil separator rises excessively e.g. in an outlet blockage situation.

Kiosks for externally mounted alarm/control panels are available. Click here for further detail.

Operation

Request A Quotation

For further information phone our sales hotline 01743 457977 or email sales@spelproducts.co.uk