SPEL Tankstor® Below Ground Tanks

SPEL Tankstor tanks are manufactured for many applications and in a wide range of specifications to handle such substances as water, sewage, farm effluent, petroleum products and chemicals.Our modern plant, equipment and quality assurance procedures ensure market-leading quality.Being manufactured in glass reinforced plastics, SPEL tanks are lightweight, easy to handle and install. They are not susceptible to rust, exhibit excellent corrosion resistant properties and have a life expectancy in excess of 50 years.For full SPEL Tankstor specification information, go to our SPEL Tankstor introduction page here.

For full SPEL Tankstor specification information, go to our SPEL Tankstor introduction page here.

Product Range

H Series | Horizontal Tanks

 

200 Series

(1.2m inside diameter):

1,000 – 10,000L capacity

 

300 Series

(1.8m inside diameter):

4,000 – 40,000L capacity

 

400 Series

(2.6m inside diameter):

13,650 – 100,000L capacity

 

500 Series

(3.5m inside diameter):

60,000 – 200,000L capacity

 

600 Series

(4.0m inside diameter):

100,000 – 300,000L capacity

 

V Series | Vertical Tanks

 

200 Series

(1.2m inside diameter):

1,700 – 5,000L capacity

 

300 Series

(1.8m inside diameter):

5,000 – 15000L capacity

 

400 Series

(2.6m inside diameter):

10,000 – 36,500L capacity

 

500 Series

(3.5m inside diameter):

50,400 – 90,100L capacity

 

600 Series

(4m inside diameter):

65,668 – 115,930L capacity

Applications

  • Stormwater attenuation
  • Fire fighting sprinkler reservoirs
  • Potable water storage
  • Septic/settlement tanks
  • Cesspools
  • Silage effluent holding tanks
  • SPEL RainSave rainwater reservoirs
  • Accidental spillage containment
  • Transformer oil dump tanks
  • Packaged pumping chambers
  • Chemical spill tanks

Shell Design

Designed with reference to BS EN 13121. All tank shells carry the SPEL 25 Year Warranty and life expectancy in excess of 50 years.

Shell Specifications

Different tank shell specifications are available dependent upon tank invert levels, ground conditions and ground water levels. (See Installation Guidance section) 

Inlet/Outlet Connections

Pipe connections available to accommodate most standard sizes.

Tank Capacity200 Series300 Series400 Series500 Series600 Series
Litres1.2m Inside dia.1.8m Inside dia.2.6m Inside dia.3.5m Inside dia.4.0m Inside dia.
1,0001,160
2,0002,040
3,0002,930
4,0003,8101,950
5,0004,700
6,0005,5782,755
7,0006,470
7,3003,200
8,0007,3463,535
9,0008,236
9,2704,015
10,0009,1204,285
12,00010,8885,070
13,65012,3475,755
16,0006,700
17,0007,060
18,2007,6154,000
20,0008,2554,400
25,00010,2155,250
27,3005,700
30,00012,1756,170
35,00014,155
36,4007,400
40,00016,120
40,6008,200
45,0005,390
45,5009,050
50,0009,950
60,00011,8306,960
70,00013,7108,520
75,00014,7009,040
80,00015,60010,040
90,000
90,40017,560
100,00011,1408,710
120,00010,310
125,00013,840
140,00011,891
150,00016,34012,690
160,00017,54013,485
170,00014,320
175,00018,940
180,00019,44015,079
190,00015,871
200,00021,54016,635
220,00018,259
240,00019,899
250,00020,651
260,00021,450
270,00022,250
280,00023,020
290,00023,850
300,00024,650
Note: Intermediate sizes are available.
Gross Tank Capacity200 Series300 Series400 Series500 Series600 Series
1.2m Inside dia.1.8m Inside dia.2.6m Inside dia.3.5m Inside dia.4.0m Inside dia.
LitresDepth (mm)Depth (mm)Depth (mm)Depth (mm)Depth (mm)
VT200VT300VT400VT500VT600
2,0002,100
2,2502,6005,500
3,0003,2006,70011,400
3,5003,8008,00014,00023,200
4,0004,3009,30016,70028,00036,000
4,5004,90010,50019,30032,80042,200
5,0005,50011,80022,00037,60048,500
5,5006,00013,10024,60042,40054,800
6,0006,60014,40027,30047,20061,100
6,5007,20015,60029,90052,10067,400
7,0007,70016,90032,60056,90073,700
7,5008,30018,20035,20061,70079,900
8,0008,80019,50037,90066,50086,200

Below is a detailed but not exhaustive selection of additional items that SPEL supply as part of the bespoke design and build package available on our Tankstor systems.

Pipe Sizes
Shafts (circular and rectangular / square)
Flow Control Devices
Pump
Platforms
Aylesbury / Float Valve
Access
Ladders
Stainless steel & GRP
Bulk Head Wall / Partitions
Structural & non-structural Half & full height
Bauer Connectors Suction Pipes

Access shafts are supplied in the following formats:

Flanged joint stub access shaft with extension shaft
Rectangular Shafts
Stub Access Shafts

SPEL extension access shafts

Extension access shafts are available for deep invert applications.

Circular access shafts are supplied in 450, 600, 700, 900 and 1200mm diameter. Rectangular shafts are supplied in 800, 900 and 1000mm X 1000/1250/1500mm. GRP ladders can be incorporated for more access, complete with stainless steel fixings.

200/300 Series

Shafts can be laminated onto the tank up to a maximum height of 1.2m. Above this height extension shafts can be supplied separately for on-site fitting during installation.

400 Series

Shafts up to 400mm high are laminated onto the tank. Above this height extension shafts can be supplied separately for on-site fitting during installation.

500 Series

Shafts up to 300mm high are laminated onto the tank. Above this height extension shafts can be supplied separately for on-site fitting during installation.

600 Series

Stub access shafts are fitted 100mm high and extension access shafts fitted as 500 series. Above this height extension shafts can be supplied separately for on-site fitting during installation.

Extension Shafts

These are supplied in 500mm increments and are available in different laminate specs to suit site-specific invert levels and applications.

Bauer Connections

Emptying/ Silt Removal

Bauer couplings are the common method of connecting flexible pipes in the water and fluid industry. SPEL offer a range of connection options, details of which can be seen below, these are usually attached to suction pipes that reach to the base of the tank, allowing the tank to be completely emptied without the need for removing heavy manhole covers.

The above shows a close coupled Bauer connector for use where the tank is located close to the surface and close to the tanker parking bay.

Standard flange coupling allows for an extension pipe to be fitted to deeper tanks and/or where the tanker parking bay is located further away from the tank.

Double Skin/ Secondary Containment Tanks

Where there is particular concern about leakages occurring from tanks, the alternative to bunding is to provide a second skin to monitor and capture leaks. Monitoring of the cavity using liquid sensing probe(s) can alert operators to a potential leak. Such systems are sometimes used for underground tanks in remote areas, where undetected leaks to the environment may occur. Similarly tanks within process buildings may also be double skin.

Examples of tanks with secondary containment for above and below ground applications

Example Installation

For a full list of additional accessories, see accessories tab above.

Request A Quotation

For further information phone our sales hotline 01743 457977, email sales@spelproducts.co.uk or Click the button below.
 

Request a Quote for SPEL Tankstor® Below Ground Tanks

Fill out the form below with your details and any info you wish to be considered by our team and we will be in touch shortly. 

Live Chat